COMMERCIAL PROJECT DOCUMENTATION

BODAQ ASTM E84 Class A documentation for commercial interiors

For a BODAQ architectural-film selection, the relevant fire documentation must be connected to the exact pattern, intended use, substrate, and project requirement—not treated as a blanket approval.

1. What an ASTM E84 Class A document means

ASTM E84 evaluates surface-burning characteristics, including flame spread and smoke development. A Class A classification is tied to the documented test result and its stated product or configuration. For BODAQ, retain the exact collection and pattern code with the manufacturer documentation rather than relying on a general catalog description.

BODAQ publishes ASTM E84 guidance and product-specific or grouped fire-test documentation. A project team should use the current source document that actually covers the intended material. Atlas Finishes™ can explain the relevant documents and help organize the documentation needed for a selected material.

2. Why the complete installed assembly matters

Architectural film does not automatically make a wall, door, panel, or room fire rated. The existing substrate, adhesive or primer, surface preparation, seams, penetrations, and underlying assembly all matter to a project review. A surface-burning report is not a fire-door listing or approval for a regulated door assembly.

For rated doors, exit routes, hospitality corridors, healthcare, or other regulated locations, the architect, code consultant, and authority having jurisdiction should identify the applicable requirement before a finish is approved.

3. What to include in a commercial submittal

Provide the BODAQ collection and pattern code, intended surface, location, substrate, product data, relevant current test report, and installation details. Also record any primers, edge details, seams, and limitations that apply to the proposal. If the pattern changes, repeat the documentation review.

Atlas Finishes™ can help assemble available manufacturer documents for the selected material and coordinate a practical project review. Final code interpretation and approval remain with the responsible project professionals and authority having jurisdiction.

DOCUMENTATION FAQ

Questions to settle before approval.

Does an ASTM E84 Class A report make every BODAQ installation code compliant?

No. The report must match the exact pattern or documented test group, intended use, substrate, installation conditions, and local project requirement.

Can a Class A film report be used as fire-door approval?

No. ASTM E84 surface-burning data does not replace product- and assembly-specific review for a rated door, frame, or other life-safety assembly.

What should a Las Vegas commercial team send for review?

Send the pattern code, surface photos, substrate details, intended location, relevant project requirements, and timing. We can help identify the next manufacturer documents to request.

START A PROJECT REVIEW

Bring the actual material details.

Send the BODAQ pattern reference, intended surface, photos, and any documentation requirement. Atlas Finishes™ will help organize the right next review.

Type a keyword to find pages.